For most offices, Cat6 is fine for desks. For new builds you plan to stay in for years, Cat6A is the safer choice because it carries 10 gigabit over the full 100 metres and handles high power PoE for modern Wi-Fi access points. Use fibre between floors, closets and buildings.
- Cat6 does 10 gigabit only up to about 55 metres.
- Cat6A does 10 gigabit up to 100 metres.
- Wi-Fi 6E and 7 access points benefit from Cat6A.
- In Canada, use FT4 or FT6 rated cable where the building requires it.
Side by side
| Cable | Max speed | Distance at max speed | Bandwidth |
|---|---|---|---|
| Cat5e | 1 Gbps | 100 m | 100 MHz |
| Cat6 | 10 Gbps | About 55 m (1 Gbps to 100 m) | 250 MHz |
| Cat6A | 10 Gbps | 100 m | 500 MHz |
| Multimode fibre (OM4) | 10 Gbps and up | Hundreds of metres | Optical |
| Single mode fibre (OS2) | 10 Gbps and up | Kilometres | Optical |
When Cat6 is enough
For desks, printers, phones and most cameras in a typical office, Cat6 gives plenty of speed for years. It is easier to install and costs less than Cat6A.
When to choose Cat6A
- New builds and long leases where you want the cabling to last.
- Wi-Fi 6E and Wi-Fi 7 access points with multi gigabit ports.
- High power PoE devices such as PTZ cameras and some access points.
- Server rooms and runs close to 100 metres.
When to use fibre
Fibre links network closets on different floors, separate buildings and data centre racks. It is immune to electrical interference and carries far more bandwidth over long distances.
Power over Ethernet
| Standard | Power at the switch port | Typical devices |
|---|---|---|
| 802.3af (PoE) | 15.4 W | Phones, basic cameras |
| 802.3at (PoE+) | 30 W | Access points, most cameras |
| 802.3bt (PoE++) | 60 W to 90 W | High end access points, PTZ cameras, displays |
Higher power PoE generates heat in cable bundles. Cat6A handles this better, which is one more reason to choose it for new installs.
Fire ratings in Canada
Cable in ceilings used for air return and between floors must meet the right fire rating. In Canada this is usually FT6 for plenum spaces and FT4 for risers. Your building or electrical inspector may have specific requirements.
How many drops to plan
- Two per desk. One for the computer, one spare or for a phone.
- One per access point. In the ceiling, planned from a Wi-Fi survey.
- One per camera. Powered over Ethernet.
- Printers, screens and POS. Wired for reliability.
- Add spares. Running extra cable during install costs far less than adding it later.
Quick answers
Is Cat6A worth the extra cost?
For new builds and long leases, usually yes.
Can we mix Cat6 and Cat6A?
Yes. Many offices use Cat6 to desks and Cat6A to access points.
Do we need fibre in a small office?
Usually not, unless you have closets on different floors or long runs.
Does cable quality affect Wi-Fi?
Yes. Access points can only be as fast as the cable feeding them.