Cabling run properly.
Structured cabling to desks, cameras, access points and printers, terminated to a patch panel, tested, and labelled at both ends. Offices, retail, warehouses and server rooms across London and the GTA.
Cat6 or Cat6A?
Cat6 handles gigabit to the desk and suits most offices. Cat6A supports 10 gigabit over full length runs and is worth it for new builds, Wi-Fi 6E and 7 access points, and anywhere you will stay ten years or more.

Tidy, tested, documented.
- Cable drops planned with you before any wall is opened
- Runs terminated to a patch panel, never loose in a ceiling
- Every run tested and certified
- Labelled at both ends to a written map
- Rat’s nest closets untangled and labelled
What each cable can carry.
Maximum speed over a full run
Where every cable goes.
Each line is a labelled, tested run back to the patch panel.
Cat5e, Cat6, Cat6A or fibre?
| Cable | Speed | Distance | Best for |
|---|---|---|---|
| Cat5e | 1 Gbps | 100 m | Basic offices, replacing old runs on a budget |
| Cat6 | 1 Gbps at 100 m, 10 Gbps up to about 55 m | 100 m | Most offices today |
| Cat6A | 10 Gbps | 100 m | New builds, Wi-Fi 6E and 7 access points, long term |
| Multimode fibre | 10 Gbps and up | Hundreds of metres | Links between floors and closets |
| Single mode fibre | 10 Gbps and up | Kilometres | Between buildings and campuses |
Our cabling standard.
Rated cable
FT4 or FT6 rated cable where the building requires it.
Patch panels
Every run terminated on a panel, never left loose.
Labelled both ends
To a written map you keep.
Tested
Every run tested, with results recorded.
Tidy pathways
J hooks and trays, not cable lying on ceiling tiles.
Clean closets
Patch cables sized and managed.
What needs a drop.
Desks
At least two drops per workstation.
Wi-Fi access points
In the ceiling, powered over the cable.
Cameras
Powered over Ethernet, no separate power needed.
Printers and copiers
Wired for reliability.
Meeting room screens
For conferencing and casting.
POS and card terminals
Wired at every till.
Network cabling, explained.

Why Cat6A for new builds
Cat6A carries 10 gigabit over the full 100 metres and handles the higher power that modern access points and cameras draw. For a space you will stay in for ten years or more, it is the safer choice.
Plenum and riser rated cable
In Canada, cable in air handling ceilings and between floors needs the right fire rating, usually FT6 for plenum spaces and FT4 for risers. We use the rating your building requires.
Power over Ethernet
PoE sends power down the network cable to access points, cameras and phones. It means fewer outlets and one place to back up power with a UPS.
Fixing a rat’s nest
Messy closets cause outages because nobody can trace a cable. We can re terminate, label and tidy an existing closet without rewiring the building.
How long does a cabling job take?
A small office often takes one or two days. Larger jobs are scheduled around your hours.
Do you work after hours?
Yes, to avoid disrupting staff.
Can you add drops to an existing office?
Yes. We plan routes that avoid opening walls where possible.
Do you provide test results?
Yes. Every run is tested and documented.
How many drops?
Rough numbers are fine. We confirm on a site visit. Data centre cabling? See data centre cabling.
Most repairs done in under an hour